Fabrication of an occlusal splint
Jul 20, 2026
Occlusal Surface Morphology: To facilitate adjustment of jaw position, the occlusal splint is generally designed and fabricated with a smooth, flat surface. For the following cases, the surface can be designed and fabricated with a cusp-fossa shape:
① Permanent (especially cast metal) occlusal splints.
② After a period of wearing a stable occlusal splint with a flat, convex surface, and a physiological therapeutic jaw position has been established, a longer period of splint wear is required to consolidate the therapeutic effect.
③ The patient needs to wear the occlusal splint and chew food all day.
④ The purpose is to utilize the cusp-fossa occlusal relationship of the splint to guide the mandible to the predetermined therapeutic jaw position.
Pivot Fulcrum: For a pivotal occlusal splint, the only posterior contact point acts as a fulcrum for mandibular rotation; therefore, its position should be carefully analyzed for leverage. If its position is too anterior, it may lose its therapeutic significance or even cause adverse reactions.
Base and clasps: Although the occlusal splint is a temporary therapeutic device for short-term use, sufficient attention should be paid to its base extension, clasp retention, surface polishing, and aesthetic effect. These factors will affect the duration of the patient's use of the occlusal splint and the therapeutic effect.